Two things. First, idle periods with vibration call for a grease with protection against false brinelling, such as LGWM 2. Second, you can tie lubrication to operating hours instead of the calendar: the wired TLSD 1-DK lubricates only when the machine is actually running, and a connected pump in counter-driven mode does the same at system level. That way the equipment stands ready in November with a full cartridge instead of an empty one.